Skip to content
24/7 EmergencyPune HQ · Fire safety products & services across India since 2008

Fire Safety Audit for Hospitals in Pune

Patients who cannot walk, oxygen in every ward and equipment running round the clock — hospital fire safety needs a detailed audit, a practical evacuation plan and trained staff.

FIRENET engineer inspecting a hose reel in a hospital corridor
🏛️Licensed AgencyMaharashtra Fire Services
🧾Form A & Form BIssued only after inspection & testing
📑Written reportPhotos, risk rating & action plan
📅Since 2008Pune, PCMC & MIDC belts

Hospitals carry the highest life-safety risk

In a hospital, many occupants cannot leave on their own. Oxygen-enriched areas, heavy electrical loads in ICUs and operation theatres, and kitchens and laundries under the same roof all raise the risk. That is why hospital fire safety goes beyond equipment — it depends on how quickly trained staff can move patients to safety.

In August 2026 the Maharashtra government ordered fire, electrical and structural safety audits of all government, private and charitable hospitals, with re-audits every six months, according to news reports. Hospitals are also covered by the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, which requires a twice-yearly maintenance certificate (Form B) from a Licensed Agency.

Areas we pay special attention to

  • ICUs, NICUs, operation theatres and recovery
  • Oxygen manifold rooms and pipelines
  • Electrical panels, UPS and DG rooms
  • Kitchens, laundries and medical stores
  • Horizontal evacuation routes and compartments
  • Staff fire training and mock drills

What We Check in Hospitals & Clinics

⚕️

Oxygen areas

Manifold rooms, cylinder storage, ignition sources and signage around oxygen use.

⚡

Electrical load

Panels, UPS rooms, overloaded sockets in wards, earthing and protection devices.

🔔

Detection & alarm

Detector coverage in wards, ducts and stores, and alarm audibility in patient areas.

🚪

Horizontal evacuation

Compartments, fire doors and routes to move bed-bound patients to a safe zone.

🧯

Firefighting

Extinguishers suited to each area (CO₂ near equipment), hose reels, hydrants and sprinklers.

👩‍⚕️

Staff readiness

Who does what in a fire, per shift — plus training and a timed mock drill.

What Audits Commonly Find in Hospitals & Clinics

Typical examples of gaps found in audits of similar buildings — not a specific client. Your report lists what we actually find at your site, with photos.

AreaTypical findingWhy it matters
ICU / OTExtension boards daisy-chained behind equipmentOverheating and fire
Oxygen manifoldOil, grease or combustible storage near cylindersIntense fire risk
CorridorsBeds, wheelchairs and trolleys parked in escape routesSlow evacuation
Fire doorsWedged open or closers removedSmoke spreads between wards
Night shiftFew staff know the evacuation planDelayed response
RecordsNo drill records or service reports on fileWeak compliance position

From Site Visit to Certificate

1

Free site visit & scope

We walk the building with you, agree the scope and share a written quote.

2

Document review

Fire approval / NOC, drawings, previous Form B, service reports and drill records.

3

Inspection & testing

Every floor, basement, terrace and plant room — systems tested where safe to do so.

4

Report with priorities

Photos, risk rating (high / medium / low) and practical fixes, usually within 3 working days.

5

Repairs & certificate

We fix what is needed, re-test and issue Form B (or Form A for new installations).

Free download · PDF

Fire Safety Audit Checklist

A practical, room-by-room checklist used by our auditors — so you can check your own building before an audit or a Form B inspection.

  • Extinguishers, hose reels, hydrants and sprinklers
  • Pump room, fire alarm and emergency lighting
  • Escape routes, refuge areas and signage
  • Electrical risks, storage and housekeeping
  • Documents: Form A, Form B, service reports and drills

See everything the free audit checklist covers →

Get the checklist

Enter your details and the PDF downloads straight away.

We may call or WhatsApp you once about fire safety for your building. No spam.

Frequently Asked Questions

How often should a hospital be audited? +

According to news reports of a Maharashtra government directive (August 2026), hospitals are expected to have fire, electrical and structural audits every six months. Separately, the twice-yearly Form B maintenance certificate applies under the Fire Act. We can align both so you are audit-ready all year.

Do you also do electrical safety audits? +

Yes. Our electrical safety audit covers panels, cabling, earthing and protection devices — the leading cause of hospital fires — and can be done in the same visit.

Can you train our nurses and ward staff? +

Yes. We run on-site fire safety training and mock drills by shift, including horizontal evacuation of bed-bound patients.

Will the audit disturb patient care? +

No. We plan the visit with your administration, avoid critical areas during procedures and only run tests at agreed times.

Recent projects

Our Work for Hospitals

Fire safety projects FIRENET has completed for similar buildings.

Healthcare

Multi-Specialty Hospital

📍 Kothrud, Pune

NFPA 99 compliant fire alarm with nurse call integration, horizontal evacuation sprinkler system, and fire compartmentation through 8 floors.

See all projects →

Fire audit for hospitals & clinics in Pune

Free site visit and written quote from a Maharashtra Fire Services Licensed Agency.